机械瓣,mechanical valve

1)mechanical valve机械瓣

1.The advantages and disadvantages of bioprosthetic valves andmechanical valves are summarized.归纳总结了生物瓣和机械瓣的优点与缺点,综合论述了组织工程心脏瓣膜和机械瓣的研究发展方向。

2.Objective This article summarized the clinical experience of 115 patients with biological andmechanical valve replacement.目的总结 115例生物瓣和机械瓣置换术的临床经验。

英文短句/例句

1.support ring for pulmonary artery of artificial heart valve人造心脏机械瓣膜肺动脉器官支撑环

2.Causes and Reoperations of Mechanical Valve Dysfunction机械瓣膜功能障碍的原因及手术对策

3.Analysing Heart Mitral valve Replacement"s Curative Effect of 107 Cases心脏机械瓣替换术(附107例疗效分析)

4.Objective The aim of this study is to sum up the experience of artificial mechanical aortic valve replacement in adults.目的总结成人主动脉瓣人工机械瓣膜置换手术的经验。

5.Analysis of thrombosis-related events in mitral valve(mechanical valve) replacement patients二尖瓣(机械瓣)置换病人抗凝期间栓塞相关并发症的原因分析

6.AVIATION MEDICAL ASSESSMENT OF MECHANICAL VALVE PROSTHESIS IN CIVIL PILOTS民航飞行员机械瓣膜置换术后的航空医学鉴定

7.Clinical Study of Warfarin Anticoagulation Therapy in Patients after Mechanical Heart Valve Replacement心脏机械瓣膜置换术后华法林抗凝治疗的研究

8.Advancement in Diagnosis and Treatment of Mechanical Prosthetic Valve Dysfunction人工机械瓣膜功能障碍诊断及治疗进展

9.Effect of ulinastatin on early postoperative cognitive function to primary simple mitral valve replacement patients乌司他丁对首次单纯二尖瓣机械瓣置换患者术后早期认知功能的影响

10.Conclusions The patients with Ⅰ to Ⅲ degree of heart function could get through pregrancy and delivery safely after CVR operation.结论心脏机械瓣膜置换术后心功能Ⅰ~Ⅲ级可安全度过孕产期。

11.Methodologic Study and Clinical Significance of Low Intensitive Anticoagulation Therapy Following Mechanical Heart Valve Replacement;心脏机械瓣膜置换术后低强度抗凝治疗的方法学研究及临床应用

12.A pilot study on low-intensity anticoagulation of HVR patients in northwest china;中国西北地区机械瓣膜置换术后低强度抗凝治疗的初步研究

13.Relationship between Patients Knowledge on Anticoagulation after Mechanical Valve Replacement and Anticoagulation Quality;机械瓣膜置换术后抗凝治疗患者教育与抗凝治疗质量的关系

14.Assessment of Mechanical Prosthetic Valves with Real-time Three-dimensional Echocardiography: An Initial Study;实时三维超声心动图评价机械瓣形态和功能的初步研究

15.Nursing intervention on mechanical heart valve replacement in patients with anticoagulant therapy after the impact of compliance护理干预对心脏机械瓣膜置换术后患者抗凝治疗依从性的影响

16.Influence of ultraviolet blood irradiation and oxygenation on plasma cytokine in patients undergoing artificial mechanical heart valve replacement under cardiopulmonary bypass添加紫外线照射充氧血预充液与人工机械瓣膜置换的炎症反应

17.Ischemic Stroke during Low Intensity Anticoagulation Therapy after Mechanical Heart Valve Replacement心脏机械瓣膜置换术后低强度抗凝治疗中的缺血性脑卒中

18.The Gastrointestinal Hemorrhage during Anticoagulation Therapy Following Mechanical Heart Valve Replacement心脏机械瓣膜置换术后抗凝治疗中的消化道出血

相关短句/例句

Mechanical prosthetic valve机械瓣

1.it introduced the anticoagulation method and test for patients accepted cardiac mechanical prosthetic valve replacement.介绍了心脏机械瓣膜置换术后抗凝的方法及其检测 ,提出护理中应重视病人住院及出院期间的健康教育 ,按要求监测国际标准化比值 ,定期随诊。

3)heart valve prosthesis st.jude medical regent valveSJMRegent机械瓣

4)st.jude medical hemodynamic plus seriesHP机械瓣

1.Before the operation and 1 year after operation,the results were compared with those of 22 patients receiving st.左心功能各项指标改善明显好于置换SJM HP机械瓣患者,部分指标接近或好于置换外径23mm瓣膜者。

5)Mechanical valve机械瓣膜

1.Objective:To evaluate the relationship between patients knowledge on anticoagulation therapy after mechanical valve replacement and their anticoagulation quality measured by INR time in therapeutic range.【目的】研究机械瓣膜置换术后患者对抗凝治疗的知晓程度与以国际标准化比值(INR)在治疗范围率为衡量标准的抗凝治疗质量间的关系。

6)Heart valve prosthesis人工机械瓣

延伸阅读

机械瓣机械瓣mechanical valve全部使用人工材料制成的心脏瓣膜代用品。其耐久性好,但致栓作用较明显,须终生抗凝治疗。常用的有笼球型、笼碟型和侧倾碟型3种类型机械瓣。20世纪70年代末出现的双叶瓣,其血流方式相当于自然心脏瓣膜的中心血流方式,是目前最新一代设计的产品,其流体力学性能优于其他类型机械瓣。